Link Interfaces Reference

V.11 & X.21 Link Pinouts

The connector shown here and pinouts described here correspond to

the connector labeled “V.11/X.21” on the back of the IOLINK-PRO & 520.

8 1

15 9

DB15 Female DTE

 

X.21

 

Direction

Contact

Circuits

Circuit

To

From

Number

Reference

Name

DCE

DCE

1

 

Protective Ground

NA

2

T (A)

Transmitted Data (A)

X

 

3

C (A)

Control (A)

X

 

4

R (A)

Received Data (A)

 

X

5

I (A)

Indication (A)

 

X

6

S (A)

Signal Element Timing (A)

 

X

7

 

----------

 

 

8

Ground

Signal Ground

NA

9

T (B)

Transmitted Data (B)

X

 

10

C (B)

Control (B)

X

 

11

R (B)

Received Data (B)

 

X

12

I (B)

Indication (B)

 

X

13

S (B)

Signal Element Timing (B)

 

X

14

 

----------

 

 

15

 

----------

 

 

Figure 3 – 8 V.11 Link Pinouts

The connecting cable must be a shielded cable.

Circuits which are paired (contain an (A) and (B) reference) should be connected to twisted pairs within the connecting cable.

NOTE For U.K. Approval:

The connecting cable should be manufactured from Belden Cable, or a cable with equivalent specifications. Each end must be terminated in a male 15 pin X.21 connector as defined in ISO-4903 1989, but one end of the cable must have UNC-4-40 screws and the other end must have M3 screws. The cable may be any length between 0 and 5M.

3.6IOLINK-PRO & 520 Reference Manual

Page 35
Image 35