Pertech A470e manual Advanced Command Language Cash Drawer Command

Models: A470e

1 37
Download 37 pages 35.36 Kb
Page 27
Image 27

A470e Users Guide

Cash Drawer

Each cash drawer driver will source 24 volts for 75 ms to the “solenoid +” pin of the appropri- ate RJ-11 jack when the proper cash drawer command is executed. The cash drawer com- mand must be preceded by a line terminator. The command for the cash drawer may vary for the Compatibility Mode selected.

 

 

 

 

 

 

 

Pin #

Cash

Cash

 

 

 

 

 

 

 

 

 

Drawer A

Drawer B

1

N /C

Solenoid +

2

Solenoid +

N /C

3

Solenoid -

Solenoid -

 

 

 

 

 

 

 

 

4

Switch

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Switch

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

N /C

N / C

 

 

 

 

 

 

 

 

Advanced Command Language Cash Drawer Command

Immediate Peripheral

ASCII Hex Decimal

DLE DC4 10 14 16 20

 

 

s: Peripheral Select

s m n

 

m: Peripheral On Time

 

n: Peripheral Off Time

 

 

Immediately generates a pulse of (m x 2 msec) followed by an off time of (n x 2 msec) on the peripheral output. If s = 00, the first peripheral on pin 2 is activated and if s =01, the second peripheral on pin 1 is activated.

Off Time should be set so that it is greater than or equal to On Time.

Buffered Peripheral Pulse

ASCII Hex Decimal

ESC p

1B 70

27 112

 

 

s: Peripheral Select

s m n

 

m: Peripheral On Time

 

n: Peripheral Off Time

 

 

Generates a pulse of (m x 2 msec) followed by an off time of (n x 2 msec) on the peripheral output. If s = 00, the first peripheral on pin 2 is activated and if s =01, the second peripheral on pin 1 is activated.

Off Time should be set so that it is greater than or equal to On Time.

A470 Command Language Cash Drawer Commands

Synopsis

ASCII

Hex

Decimal

Cash Drawer “A”

ESC

BEL

1B

07

27 7

Cash Drawer “B”

ESC

BS

1B

08

27 8

Warning: This Printer is designed for use only with Pertech Resources A470 / DH Tech- nology 4700 compatible cash drawers. Damage can result if the A470e is connected to a cash drawer that is incompatible. The cash drawer solenoid resistance must be at least 25 ohms or damage to the printer could result.

Pertech® 2006

20

Page 27
Image 27
Pertech A470e manual Advanced Command Language Cash Drawer Command, A470 Command Language Cash Drawer Commands