7.2Standard Test conditions

Unless otherwise specified, this specification is defined under the following conditions.

(1) Input signal :

As defined in Timing table, 1680 x 1050

 

non-interlaced mode (1680X1050@60Hz 146.25MHz), signal

 

sources must have 75 ohm output impedance.

(2) Luminance setting

: controls to be set to 300 nits with

 

full screen 100 % duty cycle white signal

(3) Warm up:

more than 30 minutes after power on with signal supplied.

(4) Ambient light:

400 – 600 lux.

(5)Ambient temperature: 20 ± 5 °C

7.3Test equipment

‰ Personal computer with Windows 98/2000/XP ‰ Luminance meter Minolta CA110

‰ Videogenerator: Chroma 2000, 2135, 2250 or equivalent

‰ Colour analyzer: Minolta or Chroma ‰ 10 times magnifier

‰ Ruler / Template ‰ Thickness gauge ‰ Watt / Power Meter

7.4Video Generator test sequence

Will be defined by TVI or its subcontracted quality providers.

7.5

Analog input

 

 

Analog input R,G,B level:

0 - 850 mV max.

 

Polarity:

positive, negative

 

Impedance:

75 ± 1%

 

Sync:

HV separate sync, composite sync,

7.6Optical response time

Video Bandwidth:

165 MHz (dot rate)

Typical rise time

5 ms

7.7Protection circuit

The monitor will not be damaged by:

‰missing vertical or horizontal sync pulse

‰improper vertical or horizontal sync pulse (picture must be black at improper signals, unsynchronized pictures are not allowed)

7.8DDC

The monitor can support DDC 2 B and DDC-CI according to the latest VESA standard.

7.8.1DDC Details