16

200VW8 LCD

Electronic Instructions

F/W upload instruction

Configuration and procedure (ISP Tool)

"ISP Tool " software is provided by Mstar to upgrade the firmware of Scaler IC. It is a windows-based program, which cannot be run in MS-DOS.

System and equipment requirements:

1.An i486 (or above) personal computer or compatible.

2.Microsoft operation system Windows 98/2000/XP.

3.ISP software " ISP Tool ".

(No need to install, it can be performed directly)

4.Firmware uploading tool, as shown in Fig1.

Monitor(A)

PC

Monitor (B)

 

Tographicscard

ToLPT1 port

ISPTOOL

Tomonitor

Fig. 1

*Connect the firmware uploading tool as Fig.1 shown.

*Before the servicer perform the ISP Toll program, the Communicating connection must be well done.

*When the connection fixed, power on the monitor.

Setup and perform the ISP Tool program

1.Save the software in your PC, and create a shortcut on the desktop.

2.Double click the ISP Tool. exe icon at the desktop then appears window as shown in Fig. 2.

Fig. 2

3.Press the device icon then select the matching IC type and double click it as shown in Fig. 3.

Fig. 3

4.Press the read icon, file status will shown the start address as 0X00000 and end address as 0X1FFFF. Then open the destination hex files as shown in Fig.4.

Fig. 4

5.If the hex file opened correctly, a message will be showed in the dialog box to notice the operator. At this moment, please verify the checksum of the hex file with the firmware control table to make sure the suitable file will be used. Mentioned firmware control table will be provided by supplier(Fig.5)

Fig. 5

6.Press the config icon to setting up: Port type : LPT1

Base Addr : 0X0378

E2PROM device setting : 50 (default value)

7.Press connect icon to create a linkage between PC and monitor. If the linkage was steady, a dialog box will shown as Fig. 6. At this moment, LED of monitor will be black out.

Page 16