Philips 200VW8FB Product spec, Production alignment spec, Quality Inspection spec, Operating

Models: 200VW8FB

1 74
Download 74 pages 3.15 Kb
Page 71
Image 71

200VW8 LCD

Product spec.

9300K CIE coordinates

X = 0.283 ± 0.02

 

Y = 0.297 ± 0.02

6500K/ sRGB CIE coordinates

X = 0.313 ± 0.02

 

Y = 0.329 ± 0.02

sRGB CIE coordinates

X = 0.313 ± 0.02

 

Y = 0.329 ± 0.02

Production alignment spec.

9300K CIE coordinates

X = 0.283 ± 0.005

 

Y = 0.297 ± 0.005

6500K/ sRGB CIE coordinates

X = 0.313 ± 0.005

 

Y = 0.329 ± 0.005

sRGB CIE coordinates

X = 0.313 ± 0.005

 

Y = 0.329 ± 0.005

Quality Inspection spec.

9300K CIE coordinates

X = 0.283 ± 0.015

 

Y = 0.297 ± 0.015

6500K/ sRGB CIE coordinates

X = 0.313 ± 0.015

 

Y = 0.329 ± 0.015

sRGB CIE coordinates

X = 0.313 ± 0.015

 

Y = 0.329 ± 0.015

8.13Distance between TFT LCD monitor and CRT/TFT monitor

Conducted with different modes or frequencies. No interference in a distance down to 25 cm.

9.ENVIRONMENT

9.1Environmental characteristics

71

The following sections define the interference and susceptibility condition limits that might occur between external environment and the display device.

Operating

- Temperature : 0 to 35 degree C

- Humidity

: 80% max

- Altitude

: 0-3658m

- Air pressure

: 600-1100 mBAR

Storage

 

- Temperature

: -20 to 60 degree C

- Humidity

: 95% max

- Altitude

: 0-12192m

- Air pressure

: 300-1100 mBAR

Note: recommend at 5 to 35°C, Humidity less than 60 %