Alarm
Indicator
REC
Record Button

SECTION 6: OPERATING THE DVR1 SERIES

Operating the DVR1 requires general knowledge in three areas:

Recording

Playback

Searching

Certain operating parameters must be set/programmed as part of initial startup of the DVR1. These activities are outlined in the following section.

6.1Initial Startup

On initial power-up of the DVR1, the following settings must be programmed:

Time/Date

Alarms

Password

Please refer to Main Menu Programming, Section 4 for detailed information regarding these functions.

6.2Recording

To begin recording, press REC. The message, RECORD appears briefly in the upper left- hand corner of the primary monitor. The unit always starts recording at the end of the previously recorded data.

Recording continues until one or more of the following occurs:

• Another mode is selected.

• The disk is full (No Overwrite and Overwrite Once modes). See Section 5.3 for details regarding Disk Overwrite modes.

• Video loss is detected. In the event of video loss, VIDEOLOSS will be indicated in the upper left-hand corner of the primary monitor.

1

10:55:45A

 

REC

3

 

 

 

 

2

11/17/00

 

0.2p

4

 

 

 

 

 

1.

Current Time

3.

Record Mode Indicated

 

 

2.

Current Date

4.

Normal Record Speed in

 

 

 

 

 

Pictures per Second

 

Figure 6A - LCD in Record Mode

Normal Recording

The unit records at the normal record speed until an alarm condition is detected. The normal record speed is indicated on the LCD and can be altered using Up/Down Record Speed, or in the menu system.

For information about altering the normal record speed from the menu system, see Section 4.5.

The normal record speed can be altered while the unit is recording. The unit continues recording while the menu system is active.

Alarm Recording

When an alarm condition is detected, the unit automatically switches to the alarm record speed. The alarm condition is indicated in several ways:

REC SPD

Record Speed

Buttons

The word ALARM is displayed on the primary monitor, in the upper left-hand corner of the screen.

• The red LED Alarm Indicator on the front panel of the unit is lit.

• The internal buzzer sounds, if activated via the menu. For information about activating the internal buzzer during alarms, see Section 4.3.

• By an external device connected to the alarm output of the unit (if the unit is configured with an alarm output).

The alarm record speed cannot be changed using Up/Down Record Speed on the front panel; it must be changed via the menu system. See Section 4.5 for details.

The front panel LCD displays the record speed during an alarm condition. The unit returns to the normal record speed once the alarm condition ends.

24

Page 24
Image 24
Philips DVR1EP08, DVR1EP32A, DVR1EP16 installation instructions Operating the DVR1 Series, Initial Startup, Recording