9. Maintenance
Cleaning
1.Press the Standby/On button to switch off the projector.
– The standby indicator lights up red.
2.Wait until the cooling fan has stopped (about 3 minutes after the projector has been switched off) and disconnect the power cord and all other cables.
3.Turn the projector over. Never place the projector on the side where the connections are located!
•Use a blower or lens paper to clean the lens, and be careful not to scratch or mar the lens.
Caution!
Switch off and disconnect the projector before cleaning.
1.When the cabinet is dusty, clean it by gently wiping with a soft cloth.
2.A chamois leather slightly moistened with water is sufficient for cleaning the housing.
3.If heavily soiled, use a mild detergent. Never use strong detergents or solvents such as alcohol or thinner.
Lamp replacement
Be sure to replace the lamp when the Status indicator comes on. If you continue to use the lamp after 1000 hours of usage, the lamp will turn off.
1.Press the Standby/On button to switch off the projector.
– The standby indicator lights up red.
2.Wait at least 1 hour for the lamp to cool down and the cooling fan to stop and disconnect the power cord and all other cables.
3.Turn the projector over. Never place the projector on the side where the connections are located!
4.Loosen the lamp cover securing screw.
5.Remove the lamp cover.
Always keep the lens clean
1.When the lens is dirty or dusty, first blow the dust off and then gently wipe with a soft brush or lens cleaning paper. Never touch the lens with your fingers.
2.The lens is likely to become mouldy if left dirty.
Cleaning the ventilation slots
1.Clean the ventilation slots and speaker grills on the unit periodically using a vacuum cleaner. Use a soft brush attachment when using the vacuum cleaner. Do not use a hard attachment, such as a crevice tool, to prevent the damage to the unit.
2.If accumulated dust blocks the ventilation slots, the unit will overheat, which may cause the unit to malfunction.
Lamp
The lamplife remaining can be checked using the OSD menu.
1.Press the Menu.
–The menu bar appears on the screen.
2.Use Cursor Control to move the cursor to INFORMATION.
3.Use Cursor Control to select LAMP USAGE HOURS RESET and then press OK.
The power will not turn on when the lamp hours of usage has exceeded 1100 hours. Thus, the menu cannot be displayed. In such case, replace the lamp housing, then use the following procedure to reset.
1.Connect the power cord.
–Standby status will be activated.
2.Press the Input and Auto image buttons of the main unit at the same time for 5 sec. or more. The lamp hours of usage will be reset. After resetting, the Status indicator that turned on because 1100 hours had been
Note: Obtain a replacement lamp cartridge at the store where the unit was purchased. Please specify the following information when ordering a replacement lamp cartridge:
–Model name : LC5141 (XGA) / LC5131(SVGA)
–Lamp typeLCA 3113; 12nc: 8670 931 13009
6.Loosen the three lamp cartridge securing screws. (This unit has a safety switch.)
7.Grasp the lamp holder handle and carefully pull the lamp holder out of the projector.
8.Carefully remove the new lamp housing from its package. Do not touch lamp or point lamp housing opening at anyone. Do not drop, as the impact may cause the lamp to break.
9.Place the lamp holder in the guiding slots and insert into the lamp compartment.
10.Secure the lamp cartridge with the three screws.
11.Replace the lamp cover and secure it with the securing screw.
12.Return the unit to the normal position, connect the power cable, and turn on the unit.
13.Reset LAMP HOURS RESET USAGE.