09Chapter 9
Communications/Control
64
En
About the
Communications
Interface User’s
Manual
For detailed information on the serial/LAN interface commands, download the
Serial interface specifications
This unit is equipped with a serial control interface conforming to
Caution
•It is not possible to access the
•Both the
The connectors’ pin layouts are as shown below.
| 8 | 1 | 1 | 5 |
| 15 | 9 | 6 | 9 |
|
| |||
Pin no. | Pin name | Input/ | Function |
|
|
| Output |
|
|
1 | GND | ground |
| |
2 | TxD | Output | send data |
|
3 | RxD | Input | receive data |
|
4 | DTR | Output | enable data receiving | |
5 | POWER | Input | external power control | |
6 | SW1 | Input | Extend Terminal | |
7 | SW2 | Input | Extend Terminal | |
8 | SW3 | Input | Extend Terminal | |
9 | SW4 | Input | Extend Terminal | |
10 | SW5 | Input | Extend Terminal | |
11 | SW6 | Input | Extend Terminal | |
12 | SW7 | Input | Extend Terminal | |
13 | SW8 | Input | Extend Terminal | |
14 | NC | NC (not connected on | ||
|
|
| this unit) |
|
15 | STOP_ST | Output | Stop/Play Status |
Pin no. | Pin name | Input/ | Function |
|
| Output |
|
|
|
|
|
1 | DCD | Input | NC (not connected on |
|
|
| this unit) |
|
|
|
|
2 | RxD | Input | receive data |
|
|
|
|
3 | TxD | Output | send data |
|
|
|
|
4 | DTR | Output | enable data receiving |
|
|
|
|
5 | GND | Ground | |
|
|
|
|
6 | DSR | Input | NC (not connected on |
|
|
| this unit) |
|
|
|
|
7 | RTS | Output | Connected internally to |
|
|
| CTS |
|
|
|
|
8 | CTS | Input | Connected internally to |
|
|
| RTS |
|
|
|
|
9 | RI | Input | NC (not connected on |
|
|
| this unit) |
|
|
|
|
Control functions
(a)Serial control TxD, RxD and DTR
Serial control interface conforming to
(b) Extend terminals
SW1, SW2, SW3, SW4, SW5, SW6, SW7 and SW8
This unit can be controlled by connecting switches to the exterior of these pins.
(c) External power supply control
This unit’s power can be turned on and off using the interface connector’s power pin.
Power off control is not possible when operation of the buttons on the main unit’s front panel or remote control unit is locked.
•When power is off (in the standby mode): Power turns on when L signal detected after H signal of 100 msec or greater
•When power is on: Power turns off (to the standby mode) when L signal detected after H signal of 100 msec or greater
Pin input voltage: ±12 V or less; H signal level: 4.5 V or
higher, L signal level: 0.5 V or lower