SpectraLink 6300 MCU: Facility Preparation

Required Materials Provided by Customer

Required hardware

†Rack The shelves are designed to fit into a 19” mounting rack. Each shelf measures 15” high x 19” wide x 9” deep, and weighs approximately 35 pounds fully loaded.

†Backboard Space As an alternative to rack mounting, the shelves can be wall mounted to 3/4” plywood securely screwed to a wall.

†Screws Required to mount the shelves to the wall, or to secure it in the rack. For wall mount, six #10 5/8” panhead wood screws (or similar device) are required. For rack mount, screws required are determined by the rack requirements; typically 10-32 or 1/4- 20. For multi-shelf systems, four 1.75” #8 panhead wood screws are required to secure the Intershelf Junction Panel to the backboard, along with standoffs at least 1.5” long with 1/4” inside diameter.

†Power and Conduit -48V Power Source and conduit for connection, either 1/2” BX metallic or NMX conduit. Three #8 insulated rings for use with #14 AWG wire are required for each MCS300 to be installed.

†25-Pair Cables RJ-21 male at MCU end, required to connect the shelves to the cross-connect blocks.

†Cross-Connect Blocks Required to connect the PBX ports and the Base Stations to the MCU.

†Quick Clip Fuse Required with an RCO400 Outdoor Base Station or when a Base Station is located in a separate building from the SpectraLink 6300 MCU. Recommended Quick Clip Fuse is available from Reliable Electric, Model # RSCP-2.

†Ladder Polycom installation crew will require a ladder to reach the Base Station locations. Ensure that a ladder of adequate height is available for the crew’s exclusive use upon arrival.