SpectraLink 6300 MCU: Facility Preparation
Install Intershelf Junction Panel
The Intershelf Junction Panel (JPI300) is to be installed only in restricted access areas (dedicated equipment rooms, equipment closets, or the like), in accordance with Articles
The expansion shelf controllers of shelves 2 through 20 are connected to the system controller by an intershelf junction panel. The panel converts the
Install the panel in the rack or on the wall adjacent to the Primary Shelf, which contains the system controller (CSC306 or CSC320).
Wall mounting requires 1.75” #8 panhead wood screws. The panel must be mounted with standoffs at least 1.5” long and 1/4” inside diameter.
Connect Power to Shelves
Polycom recommends that a licensed electrician install the
When connecting the
A 30 amp circuit breaker must be present on the
The DC input to the power supply is polarity sensitive. Incorrect hookup will prevent normal operation of the system and may cause damage. Double check polarities before making any connections. Verify that the DC power switch on each shelf is OFF.
42 | PN: |