Polycom JPI300, MCS300, 1725-36122-001 manual Terminate Cables at Base Station Locations

Models: JPI300 1725-36122-001 MCS300

1 68
Download 68 pages 40.07 Kb
Page 28
Image 28

SpectraLink 6300 MCU: Facility Preparation

Run all cable before attaching the RJ-45 connectors to the Base Stations. Label both the demarcation block end and the Base Station end of each wire with the Base Station number using a wire tie marker or other form of marker.

Remove bridge taps, multiples, or “Y” connections to the Base Station wires; these will cause data transmission errors. When using IDFs be sure that the total wire length from the MCU to each Base Station does not exceed 6,000 cable feet.

The area above some suspended ceilings is used as an environmental air plenum. The NEC requires that wire that is installed in plenums be rated for plenum installation.

Terminate Cables at Base Station Locations

Terminate cable at the Base Station using an RJ-45 modular crimp-on plug.

To avoid damage to the connectors or crimps, be sure to run the wire to the Base Station before connecting the RJ-45 connectors.

After running the wire to the Base Station location, terminate the wire using an RJ-45 modular crimp-on plug. Connect the data pair to pins

1 and 2 and the power pair to pins 7 and 8. These connections are not polarity sensitive.

1

8

RJ-45 Modular Cable

28

PN: 1725-36122-001_M.doc

Page 28
Image 28
Polycom JPI300, MCS300, 1725-36122-001 manual Terminate Cables at Base Station Locations