Additional Service

Disassembly or service of the air compressor beyond what is covered in this manual is not recommended. If additional service is required, contact your near- est Authorized Warranty Service Center.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and perform sched- uled maintenance as necessary.

2.Set the Auto/Off lever to "Off".

3.Close the globe valve.

4.Remove the air tool or accessory.

5.Open the globe valve and allow the air to slowly bleed from the air tank until tank pressure is approximately 20 psi.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air tank. If not drained, water will cor- rode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the air hose from damage (such as being stepped on or run over).

REPLACEMENT PARTS SERVICE

Use only identical replacement parts. For a parts list or to order parts, visit our service website at www.deltaportercableservicenet.com. You can also order parts from your nearest PORTER-CABLE Factory Service Center or PORTER-CABLE Authorized Warranty Service Center. Or, you can call our Customer Care Center at (888) 8485175.

SERVICE AND REPAIRS

All quality tools will eventually require servicing and/or replacement of parts. For infor- mation about PORTER-CABLE, its factory service centers or authorized warranty ser- vice centers, visit our website at www.deltaportercable.com or call our Customer Care Center at (888) 848-5175. All repairs made by our service centers are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others.

You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include all of the information shown on the nameplate of your tool (model number, type, serial number, etc.).