and Adjustments section. Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts. Before servicing unit unplug or disconnect elec- trical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

 

 

 

CORRECTION

Excessive

Pressure switch does

 

Move Auto/Off lever to the "Off"

tank pressure

not shut off motor when

 

position, if the unit does not shut off

- safety valve

compressor reaches

 

contact a Trained Service Technician.

pops off

"cut-out" pressure.

 

 

 

 

 

 

Pressure switch "cut-

 

Contact a Trained Service Technician.

 

out" too high.

 

 

 

 

 

Air leaks at

Tube fittings are not

 

Tighten fittings where air can be

fittings

tight enough.

 

heard escaping. Check fittings

 

 

 

with soapy water solution.

 

 

 

DO NOT OVER TIGHTEN.

Air leaks at

Check valve seat

 

A defective check valve results in

or inside

damaged.

 

a constant air leak at the pressure

check valve

 

 

release valve when there is pressure

 

 

 

in the tank and the compressor

 

 

 

is shut off. Replace check valve.

 

 

 

Refer the To Replace or Clean

 

 

 

Check Valve in the Service

 

 

 

and Adjustments section.

Air leaks at

Defective pressure

 

Contact a Trained Service Technician.

pressure switch

switch release valve.

 

 

 

 

 

release valve

 

 

 

 

 

 

Air leaks in air

Defective air tank.

 

Air tank must be replaced.

tank or at air

 

 

Do not repair the leak.

tank welds

 

 

 

 

 

Risk of bursting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or otherwise

 

 

modify air tank or it will weaken.

 

 

The tank can rupture or explode.

Air leaks

Leaking seal.

 

Contact a Trained Service Technician.

between head

 

 

 

 

 

 

and valve plate

 

 

 

 

 

 

Pressure

It is normal for "some"

 

If there is an excessive amount of

reading on

pressure drop to occur.

 

pressure drop when the accessory

the regulated

 

 

is used, adjust the regulator as

pressure gauge

 

 

instructed in the Operation section.

(if equipped)

 

 

NOTE: Adjust the regulated

drops when

 

 

pressure under flow conditions

an accessory

 

 

(while accessory is being used).

is used

 

 

 

 

 

 

Air leak from

Possible defect in

 

Operate safety valve manually

safety valve

safety valve.

 

by pulling on ring. If valve still

 

 

 

leaks, it should be replaced.

N020206