PROBLEM | CAUSE | CORRECTION |
Compressor is | Prolonged excessive | Decrease amount of air usage. |
not supplying | use of air. |
|
enough air | Compressor is not large | Check the accessory air |
to operate | enough for air requirement. | requirement. If it is higher than |
accessories |
| the SCFM or pressure supplied |
|
| by your air compressor, you |
|
| need a larger compressor. |
| Hole in hose. | Check and replace if required. |
|
|
|
| Check valve restricted. | Remove and clean, or replace. |
| Air leaks. | Tighten fittings. |
| Restricted air intake filter. | Clean or replace air intake filter. |
|
| Do not operate the air compressor |
|
| with the filter removed. Refer |
|
| to the Air Filter paragraph in |
|
| the Maintenance section. |
| Loose belt. | Loosen wingnut and then |
|
| tighten wingnut until it contacts |
|
| the washer, plus one turn. |
Restricted | Dirty air filter. | Clean or replace. See Air |
air intake |
| Filter paragraph in the |
|
| Maintenance section. |
Motor will | Motor overload protection | Refer to Motor Overload Protection |
not run | switch has tripped. | under Operation. If motor overload |
|
| protection trips frequently, contact |
|
| a Trained Service Technician |
| Tank pressure exceeds | Motor will start automatically when |
| pressure switch "cut- | tank pressure drops below "cut- |
| in" pressure. | in" pressure of pressure switch. |
| Check valve stuck open. | Remove and clean, or replace. |
| Loose electrical | Check wiring connection |
| connections. | inside pressure switch and |
|
| terminal box area. |
| Possible defective motor | Have checked by a Trained |
| or starting capacitor. | Service Technician. |
| Paint spray on internal | Have checked by a Trained Service |
| motor parts. | Technician. Do not operate the |
|
| compressor in the paint spray area. |
|
| See flammable vapor warning. |
| Pressure release valve on | Bleed the line by pushing the |
| pressure switch has not | lever on the pressure switch to |
| unloaded head pressure. | the "Off" position; if the valve |
|
| does not open, replace switch. |
21 - ENG | N020206 |