Troubleshooting – Mechanical and Electrical Problems

Trouble

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

 

Verify machine is connected to power

No incoming power.

source, and that the safety key is

 

installed on the switch.

 

 

Cord damaged.

Replace cord.

 

 

 

Re-set the overload by pushing in

 

completely the OFF (red) button on

Overload automatic reset has not

the magnetic switch. Allow a few

been reset.

minutes for the machine to cool. If

 

problem persists, check amp setting

 

on the motor starter.

 

 

 

One cause of overloading trips which

 

are not electrical in nature is too

 

heavy a cut. The solution is to reduce

 

feed pressure into the blade. If too

 

heavy a cut is not the problem, then

Band Saw frequently trips.

check the amp setting on the overload

 

relay. Match the full load amps on the

 

motor as noted on the motor plate. If

 

amp setting is correct then there is

 

probably a loose electrical lead.

 

Check amp setting on motor starter.

 

 

 

Verify that band saw is on a circuit of

Building circuit breaker trips or fuse

correct size. If circuit size is correct,

there is probably a loose electrical

blows.

lead. Check amp setting on motor

 

 

starter.

 

 

 

If you have access to a voltmeter, you

 

can separate a starter failure from a

 

motor failure by first, verifying

 

incoming voltage at 220+/-20 and

 

second, checking the voltage

Switch or motor failure (how to

between starter and motor at 220+/-

distinguish).

20. If incoming voltage is incorrect,

 

you have a power supply problem. If

 

voltage between starter and motor is

 

incorrect, you have a starter problem.

 

If voltage between starter and motor

 

is correct, you have a motor problem.

 

 

 

Clean motor of dust or debris to allow

Motor overheated.

proper air circulation. Allow motor to

cool down before restarting.

 

 

 

If electric motor is suspect, you have

 

two options: Have a qualified

Motor failure.

electrician test the motor for function

or remove the motor and take it to a

 

 

qualified electric motor repair shop

 

and have it tested.

 

 

34

Page 34
Image 34
Powermatic PM1800 operating instructions Troubleshooting Mechanical and Electrical Problems