Introduction

This manual is provided by Powermatic covering the safe operation and maintenance procedures for a Powermatic Model PM1800 Band Saw. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. This machine has been designed and constructed to provide years of trouble free operation if used in accordance with instructions set forth in this manual. If there are any questions or comments, please contact either your local supplier or Powermatic. Powermatic can also be reached at our web site: www.powermatic.com.

Specifications

 

 

Model Number

PM1800

Stock Number (5HP 1PH)

1791800

Stock Number (5HP 3PH)

1791801

Motor (1PH)

TEFC, 5HP, 1PH, 230V, 60Hz, 21A

Motor (3PH)

TEFC, 5HP, 3PH, 230/460V (pre-wired 230V)*, 60Hz, 13/6.5A

Blade Speeds (SFPM)

1800 and 4200

Maximum Cutting Height/Resaw Capacity (in.)

18

Throat Capacity (in.)

18

Minimum Blade Width (in.)

1/16

Maximum Blade Width (in.)

1-1/2

Blade Length (in.)

160 to 161-1/2

Blade provided (in.)

Hook Type, 3/4 W x 0.03 Thk, 4TPI

Resaw Fence (L x H)(in.)

30 x 6-1/2

Resaw Pin (Dia. x H)(in.)

2 x 6-1/2

Table Dimensions (L x W x Thk)(in.)

24 x 24 x 2

Table Thickness (in.)

2

Table Tilt (deg.)

45 right, 15 left

Table Height from Floor @ 90 deg. (in.)

37-1/2

Miter Gauge Positive Stops (deg.)

45 and 90

Wheel Diameter (in.)

18-1/2

Power Transfer

poly-V belt drive

Switch

magnetic, with power indicator lamp

Dust Port Diameter (in.)

4

Dust Collection CFM Required

400

Overall Dimensions (L x W x H)(in.)

38 x 42 x 81-1/2

Net Weight (lbs.)

806

Shipping Weight (lbs.)

902

*NOTE: For 460V operation, magnetic switch (part no. PM2000-293C) must be purchased separately and installed. A qualified electrician is recommended.

The above specifications were current at the time this manual was published, but because of our policy of continuous improvement, Powermatic reserves the right to change specifications at any time and without prior notice, without incurring obligations.

7

Page 7
Image 7
Powermatic PM1800 operating instructions Introduction Specifications