Primera Technology LX200 Adjusting the Label Stock TOF TOP of Form Sensor, Circular Labels

Models: LX200

1 45
Download 45 pages 19.8 Kb
Page 13
Image 13

TOC

INDEX

E. ADJUSTING THE LABEL STOCK TOF (TOP OF FORM) SENSOR

If you are using label stock other than standard square / rectangular die cut labels such as circular die-cut labels or through-hole stock use the instructions below to adjust the label stock TOF sensor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5

1.0

1.5

2.0

mm

12.7

25.4

38.1

50.8

Label Stock Sensor Bar

Circular Labels

If you are using Circular Labels you must adjust the Stock sensor to correspond with the very top of the label where the circles are closest together. If the sensor is too far to the right or the left the printer will still sense the label but the image may be offset downward because the printer will start printing at the wrong position. If you are using stock that has multiple labels across make sure the sensor corresponds to a place on the stock that has a label and not a vertical gap.