DVR User’s Manual

4.5.3RS485 Setup

The DVR series unit controls the domes via RS-485 communication protocol. The RS-485 parameters in the DVR series unit must be set to the same parameters set in dome camera.

Users are allowed to change the RS-485 settings of the DVR series unit. Select <System Setup> in Main menu, then select <RS485 Setup> from the System Setup menu and press ENTER. The following menu is displayed.

 

 

RS485 Setup

1

Unit ID

224

2

Baud Rate

9600

3

Bits

8

4

Stop

1

5

Parity

None

The ID number must match the ID address set by the dome. The Unit ID is in the range of 1 to 255. The default ID is 224. Note that there cannot be any two devices on the same bus given the same ID address, or a conflict may occur.

The default RS-485 settings of the DVR series unit are 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity.

NOTE: The settings become effective after saving the changes and exiting from the menu.

4.5.4Dome Controlling Keys

The functions of some keys in dome control mode are totally different from normal status function. Please refer to Setup Guide for the graphical illustration of functional keys.

Set / Go Preset

This key is used to enter the Dome Preset menu to set up certain position as a preset and go to the predetermined preset positions for viewing.

34

Page 35
Image 35
Proficient Audio Systems 00P3DG090DSEB3 user manual 3 RS485 Setup, Dome Controlling Keys, Set / Go Preset