Tsunami MP.11and MP.11a Installation and Management
Resetting Hardware
If the MP.11/a does not respond for some reason and you are not able to reboot, you can restart by
means of a hardware reset. This restarts the MP.11/a hardware and embedded software. The last
saved configuration is used. Any changes that you have made since then are lost.
To reset the hardware, press and release the RESET button on the MP.11/a unit with, for example, a
pencil.
Soft Reset to Factory Default
If necessary, you can reset the MP.11/a to the factory default settings. This must be done only when
you are experiencing problems. Resetting to the default settings requires you to again configure the
MP.11/a.
To reset to factory default settings:
1. Click the Commands button, then the Reset tab.
2. Click the Reset to Factory Default button. The device configuration parameter values are reset to
their factory default values.
If you do not have access to the MP.11/a, you can use the procedure described in “Hard Reset to
Factory Default” on page 106 as an alternative.
Chapter 4. Basic Management 29
CPN 65755 Issue Date: August 2003