Chapter 8: Specifications

 

 

High-Capacity (Model WA3006)

 

 

 

 

Description

Condition

Test Condition/Result

 

 

 

 

 

 

After a standard discharge,

Protection circuit board to operate.

 

Reverse Charging Test

reverse-charge continuously at

 

No explosion, fire, smoke, or leakage.

 

 

4.2V and 4A for 8hrs.

 

 

 

 

8.3.1.4Safety License

 

Item

License

 

 

Standard

 

 

 

 

 

 

 

 

1

UL 1642

 

 

The lithium-ion cell has been listed and pass the UL1642 stan-

 

 

 

dard by UL Lab.

 

 

 

 

 

 

2

UL 2054

 

 

The battery pack is in the process to apply the UL 2054 battery

 

 

 

standard.

 

 

 

 

 

 

 

 

3

89/336 EEC-EMC

 

The battery pack is in the process to apply the below standard:

 

directive.

 

 

-EN55022 -LVD 72/23 EEC -EN55024 -EN61326

 

 

 

 

 

4

RoHS Directive

 

The battery pack is in the process to apply the RoHS directive

 

 

applicable report by SGS Lab.

 

 

 

 

 

8.3.1.5

Environmental Test

 

 

 

 

 

 

 

Description

Test

Reference

Test Condition/Result

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop sample battery on all faces from height of

 

Drop

 

(mechanical)

1.2 meters onto concrete floor.

 

 

No explosion, fire, vent, leakage and the open

 

 

 

 

 

 

 

 

 

 

 

 

circuit voltage higher than 3.7V.

 

 

 

 

 

 

 

 

Storage at high temp.

EN60068-2-2 Test

+60°C dry for 240 hours

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

Storage at low temp.

EN60068-2-1 Test

-20°C dry for 240 hours

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

Storage at high temp.

IEC68-2-3 Test

+40°C at 90%RH for 240 hours.

 

and high humidity

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

+60oC (2C) for 1 hour (T1), -20oC (2C) for 1

 

Storage temp. cycling

IEC68-2-14 Test

hour. 3 minutes Max allowed for change

 

between T1 and T2.

 

 

 

 

 

 

Cycle 10 times

 

 

 

 

 

 

No explosion, no fire, no vent, and no leakage.

 

 

 

 

 

 

After standard charge, tested under the following

 

 

 

 

 

 

conditions: Random vibration 5Hz-500Hz ASD

 

Vibration resistance

BS2011 Part 2.1

0.02g2/Hz in 3 axis for 15 mins. After which,

 

FDC (IEC68-2-37)

carry out a standard discharge, charge, discharge.

 

 

 

 

 

 

 

 

 

No parting joints/cracks or damage to connec-

 

 

 

 

 

 

tors. No leakage or critical damage.

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 307