Chapter 8: Specifications

 

 

 

 

 

 

Super High-Capacity (Model WA3010)

 

 

 

 

 

 

 

 

 

 

Item

License

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

2

UL 2054

 

 

The battery pack is in the process to apply the UL 2054 battery

 

 

 

 

standard. File No. MH29921.

 

 

 

 

 

 

 

 

3

89/336 EEC-EMC

 

The battery pack is in the process to apply the below standard:

 

 

directive

 

 

-EN55022 -LVD 72/23 EEC -EN55024 -EN61326

 

 

 

 

 

 

 

4

RoHS Directive

 

The materials of battery pack are used in accordance with the

 

 

 

European RoHS directive.

 

 

 

 

 

 

 

8.3.2.5

Environmental Test

 

 

 

 

 

 

 

 

 

 

Description

Test

Reference

Test Condition/Result

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop sample battery on all faces from height of

 

 

 

Drop

 

(mechanical)

1.2 meters onto concrete floor.

 

 

 

No explosion, fire, vent, leakage and the open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit voltage higher than 3.7V.

 

 

Storage at high temp.

EN60068-2-2 Test

+60°C dry for 240 hours

 

 

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

Storage at low temp.

EN60068-2-1 Test

-20°C dry for 240 hours

 

 

 

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

Storage at high temp.

IEC68-2-3 Test

+40°C at 90%RH for 240 hours.

 

 

 

and high humidity

No explosion, fire, vent or leakage.

 

 

 

 

 

 

 

 

 

 

 

 

 

+60°C (2C) for 1 hour (T1), -20oC (2C) for 1

 

 

 

 

 

 

 

 

hour. 3 minutes Max allowed for change

 

 

Storage temp. cycling

IEC68-2-14 Test

between T1 and T2.

 

 

 

 

 

 

 

Cycle 10 times

 

 

 

 

 

 

 

No explosion, no fire, no vent, and no leakage.

 

 

 

 

 

 

 

After standard charge, tested under the following

 

 

 

 

 

 

 

 

conditions: Random vibration 5Hz-500Hz ASD

 

 

Vibration resistance

BS2011 Part 2.1

0.02g2/Hz in 3 axis for 15 mins. After which,

 

 

FDC (IEC68-2-37)

carry out a standard discharge, charge, discharge.

 

 

 

 

 

 

 

 

 

 

 

 

No parting joints/cracks or damage to connec-

 

 

 

 

 

 

 

tors. No leakage or critical damage.

 

 

Impact shock resis-

-

 

 

3 cycles of 50G 11ms, 1/2 sine pulse acceleration

 

 

 

tance

 

 

 

applied in 6 directions. 18 shocks total.

 

 

 

 

 

 

 

 

 

ESD protection

-

 

 

Accordance with EN61000-4-8

 

 

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 311