Chapter 5: Settings
Imager
186 WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual

Barcodes Must Decode

This parameter specifies the minimum number of bar codes that the imager must
decode in order to report success.
Note: This number must be less than the number of bar codes assigned to
“Max Number Barcodes”. The driver validates and reassigns the value
if necessary.

Window Width

“Window Width” determines the width of the captured image in pixels.
Note: The driver will validate and reassign the value assigned to this parameter,
if necessary; the driver will also use the Window Width value to horizon-
tally center the image in the field of view.

Window Height

This parameter determines the height of the captured image in pixels.
Note: The driver will validate and reassign the value assigned to this parameter,
if necessary; the driver will also use “Window Height” value to vertically
center the image in the field of view.

Dot Time (msec)

The value selected for “Dot Time (msec)” determines (in milliseconds) how long
the targeting dot remains on before the scanner begins capturing images. When you
double-tap on this parameter, a dialog box is displayed in which you can enter a
value of between 0 and 3000. A value of 0 disables the target dot.

5.27.4.2 Advanced Options – Imager

Important: Do not adjust the advanced options without first consulting Psion
Teklogix technical support.

Factory Defaults On Reboot

The value assigned to this parameter determines whether or not the driver will
restore the factory defaults to the imager device on the next reboot.
Note: The driver will default the imager device on a ‘clean’ reset, regardless of
the value of this parameter.