Psion Teklogix ISO 9001 user manual Description Condition Standard

Models: ISO 9001

1 360
Download 360 pages 6.83 Kb
Page 328
Image 328

Chapter 8: Specifications

Super High-Capacity (Model WA3010)

Description

Condition

Standard

 

 

 

 

After standard charge, carry out 5 cycles of the fol-

 

 

lowing: 65°C and 90% humidity for 8 hrs.

 

Temp./Humidity

25°C and 65% humidity for 4 hrs.

 

-20°C for 8 hrs. 25°C and 65% humidity for 4 hrs.

100 minutes or more

Cycle

Following that, perform a fast discharge, standard

 

 

 

 

charge and then a fast discharge. Measure the time

 

 

taken for the second discharge.

 

 

After standard charge, keep the battery at 60°C for 8

 

Dry heat

hrs. Carry out a fast discharge, standard charge and

100 minutes or more

then a fast discharge. Measure the time taken for the

 

 

 

second discharge.

 

 

 

 

 

The battery will need to pass the requirements of the

 

EMC/CE Testing

EMC directive 89/336/EEC (and amendments) when

Test to be performed

fitted into the product:

by manufacturer.

 

Emissions to EN55022 Class B (1998) Immunity to

 

 

 

EN55024 (1998)

 

 

EN61000-4-8:

 

Electro-Static Dis-

A. Contact Discharge: +/-8kV for each contact pad

 

by 10 times.

No damage

charge Test

B. Air Discharge: +/-15kV for 10 times (the dis-

 

 

 

 

charge test point is for around battery casing.)

 

8.3.2.3Safety Data

Description

Condition

Test Condition/Result

 

 

 

Short Circuit Test

After a standard charge, short

Protection circuit board to operate.

terminals and discharge for 1 hr.

No explosion, fire, smoke, or leakage.

 

 

After a standard charge, charge

Protection circuit board to operate.

Over Charging Test

continuously at 4.2V and 4A for

No explosion, fire, smoke, or leakage.

 

8 hrs.

 

 

 

 

 

 

After a standard discharge,

Protection circuit board to operate.

Reverse Charging Test

reverse-charge continuously at

No explosion, fire, smoke, or leakage.

 

4.2V and 4A for 8hrs.

 

 

 

 

 

8.3.2.4Safety License

Item

License

Standard

 

 

 

1

UL 1642

The lithium-ion cell has been listed and pass the UL1642 stan-

dard by UL Lab. File No. MH12383

 

 

310WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual

Page 328
Image 328