Chapter 8: Specifications

High-Capacity (Model WA3006)

 

Description

 

Condition

 

Standard

 

 

 

 

 

 

 

 

 

 

After standard charge, apply a standard discharge

 

 

Over Discharge

followed by a standby discharge. Then measure

110 minutes or more

 

capacity after carrying out standard charge and then a

 

 

 

 

 

 

 

fast discharge.

 

 

 

Self discharge

 

After a standard charge, keep battery at 25°C for 30

100 mins or more

 

 

days. Measure the time taken for a fast discharge.

 

 

 

 

 

 

 

Perform a standard charge and fast discharge at 0°C,

100 mins. @ 0°C

 

Temperature

 

25°C and 40°C and measured the time taken for a

110 mins. @ 23°C

 

 

 

fast discharge at 25°C.

 

105 mins. @ 40°C

 

 

 

After standard charge, carry out 5 cycles of the fol-

 

 

 

 

lowing: 65°C and 90% humidity for 8 hrs.

 

 

Temp./Humidity

25°C and 65% humidity for 4 hrs.

 

 

 

-20°C for 8 hrs. 25°C and 65% humidity for 4 hrs.

100 minutes or more

 

Cycle

 

 

 

Following that, perform a fast discharge, standard

 

 

 

 

 

 

 

 

charge and then a fast discharge. Measure the time

 

 

 

 

taken for the second discharge.

 

 

 

 

 

After standard charge, keep the battery at 60°C for 8

 

 

Dry heat

 

hrs. Carry out a fast discharge, standard charge and

100 minutes or more

 

 

then a fast discharge, measured the time taken for the

 

 

 

 

 

 

 

second discharge.

 

 

 

 

 

 

 

 

 

 

 

 

The battery will need to pass the requirements of the

 

 

EMC/CE Testing

EMC directive 89/336/EEC (and amendments) when

Test to be performed

 

fitted into the product:

 

 

 

by manufacturer.

 

 

 

Emissions to EN55022 Class B (1998) Immunity to

 

 

 

 

 

 

 

EN55024 (1998)

 

 

 

 

 

EN61000-4-8:

 

 

 

Electro-Static Dis-

A. Contact Discharge: +/-8kV for each contact pad

 

 

by 10 times.

 

No damage

 

charge Test

 

 

 

 

B. Air Discharge: +/-15kV for 10 times (the dis-

 

 

 

 

 

 

 

 

charge test point is for around battery casing.)

 

8.3.1.3

Safety Data

 

 

 

 

 

 

 

 

Description

 

Condition

Test Condition/Result

 

 

 

 

 

 

 

Short Circuit Test

 

After a standard charge, short

Protection circuit board to operate.

 

 

terminals and discharge for 1 hr.

No explosion, fire, smoke, or leakage.

 

 

 

 

 

 

 

 

After a standard charge, charge

Protection circuit board to operate.

 

Over Charging Test

 

continuously at 4.2V and 4A for

 

 

No explosion, fire, smoke, or leakage.

 

 

 

 

8 hrs.

 

 

 

 

 

 

 

 

 

 

 

 

 