Terminal Block Connector

The terminal block connector requires the following assembly.

1.Strip the wires to 7 ~ 8 mm.

2.Insert the wires into the male part of the connector according to the operating mode you are using. See (Figure 31).

3.Use a flat‑tip screwdriver to secure the wires. Tighten the screws to 6 in.‑lbs.

4.Insert the plug into the receptacle on the amplifier.

5.Use a flat‑tip screwdriver to secure the connector. Tighten the screws to 6 in.‑lbs.

STEREO and PARALLEL INPUTS mode:

Wire as shown by loudspeaker symbols 1 and 2 on the back of the amplifier, and as shown by the solid wires in the diagram.

Bridge MONO mode:

Wire as shown by BRIDGE MONO loudspeaker symbol on the amplifier, and as shown by the dashed wires in (Figure 31).

— Figure 31 —

Terminal Block Connector Wiring

UL

IEC

 

 

 

Wire range

6 mm2

 

 

 

Solid wire (AWG)

28 – 10

 

 

 

Stranded wire (AWG/mm2)

28 – 10

 

 

 

Torque (lb.‑in.)

6

 

 

 

Wire strip length

7 – 8 mm

 

 

 

— Table 3 —

14