Rackmount Solutions RP-117QD, RP-W819QD manual Chapter, Quad Display On-screen Menu, Status, P.38

Models: RP-1020QD RP-119QD RP-117QD RP-W922QD RP-120QD RP-919QD RP-W119QD RP-817QD RP-W819QD

1 48
Download 48 pages 34.05 Kb
Page 42
Image 42
STATUS

11.5 Quad Display On-screen Menu

Chapter 11

2 Page 2 of the setup menu- Alarm Setting

Push Setup buttons (#1, #2) simultaneously and push (#1) button again to display page 2 of the setup menu on the screen. This Alarm Setting menu is used to set the desired alarm configuration like buzzer, V-loss alarm and V-loss relay.

 

ALARM SETTING

 

CH

SENSOR

TYPE

STATUS

1

OPEN

NO

ON

2

OPEN

NO

ON

3

OPEN

NO

ON

4

OPEN

NO

ON

SENSITIVITY:

 

0.3 S

DURATION:

 

30 S

BUZZER:

 

 

ON

V-LOSS ALARM:

 

ON

V-LOSS RELAY:

 

OFF

2.1 Sensitivity:

The features are not applicable in these model.

2.2 Alarm Hold Duration:

The features are not applicable in these model.

2.3 Buzzer:

The device has a build-in buzzer to signal a detected alarm through sound. User can choose to disable the buzzer by setting it to OFF.

2.4 V-Loss Alarm:

This entry is used to enable or disable the video loss alarm. The device automatically detects loss of video at any input if this entry is set to ON. User can choose to disable this feature by setting it to OFF for applications like video conferenc- ing or others that will need constant video source switching.

2.5 V-Loss Relay Control:

The device is equipped with an alarm controlled relay, which can be activated by both sensor trigged alarm and video loss alarm. This entry allows user to disable the relay activation from a loss of video in any camera input.

3 Save the settings and exit Setup Menu mode

Push (#1) button again will allow you to save the settings and go back to the normal operation mode and show a quad display on the screen.