b7 - b4: Sensor Activated Alarm

11.3 Remote Control Connection & Operation

Chapter 11

BYTE 2: Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each channel; next 4 bits show the video loss alarm status of each channel. The digit “1” means alarm event is detected, and “0” means no alarm event is detected.

b7 - b4: Sensor Activated Alarm

b3 - b0: Video Loss Alarm

 

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CH4

CH3

CH2

CH1

CH4

CH3

CH2

CH1

Sensor activated Alarm 0001 = CH1 activated 0010 = CH2 activated 0100 = CH3 activated 1000 = CH4 activated

Video Loss Alarm 0001 = CH1 activated 0010 = CH2 activated 0100 = CH3 activated 1000 = CH4 activated