11.3 Remote Control Connection & Operation

Chapter 11

2.3The configuration of the status code for both normal and alarm operations:

There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the unit.

BYTE 1

BYTE 2

}

} }

}

START

STOP START

STOP

BYTE 1: Status code for normal operation modes

 

 

 

 

 

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCK

VCR

SEQU

QUAD

CH4

CH3

CH2

CH1

Channel Select

1110 = CH1

1101 = CH2

1011 = CH3

0111 = CH4

Display Mode

0 = Quad screen display

1 = Full Screen display

Auto-sequencing mode

0 = Auto sequencing mode

1 = Quad or full screen mode

VCR mode

0 = VCR operation

1 = Live operation

Security Lock mode

0 = Security lock ON mode

1 = Security lock OFF mode

Menu Setup mode

00 = Menu setup mode

P.34

Page 38
Image 38