Operation with a Full Function Handset |
4.When GROUP appears, press the ENT key. GrP appears on the 7- segment display and the registered Group MMSI number appears on the dot matrix display.
INDV |
|
| ENT | |
|
|
|
|
|
|
|
|
|
|
Group MMSI number
Only appears if Group MMSI number is set up via DSC Operation in Menu Mode
Note: Since only one group MMSI number can be registered at a time, only one MMSI number can be displayed when GROUP is selected. To change the group MMSI number, see section 4.5.3.4.
5.Press ENT to accept the MMSI number.
6.Use the SQ UP/DOWN key to select the Working Channel for communication.
7.When the desired channel number appears, press ENT. The dot matrix display scrolls between the Working Channel and the Group MMSI number.
8.If this information is correct, press ENT to accept. A new message appears, prompting you to press the PTT key.
9.Press PTT. The radio changes over to the selected Working Channel without waiting for acknowledgment.
ENT
MMSI number | Select Working Chanel |
| |
| with SQ UP/DOWN key |
ENT
Scrolls between Working Chanel and MMSI number
ENT PTT