Regency CLASSIC
A= Clearance above grade, veranda, porch, deck, or balcony | H= *Not to be installed above a meter/regulator assembly within 36" |
[*12" (30 cm) min.] | (90 cm) horizontally from the |
B= Clearance to window or door that may be opened [*12" (30cm)] | J= clearance to service regulator vent outlet [*min. 36" (90cm)] |
C= Clearance to permanently closed window min. 12" (30 cm) | K= clearance to |
D= Vertical clearance to ventilated soffit located above the terminal within a horizontal | the combustion air inlet to any other appliance [*12 inches] |
distance of 24" (60 cm) from the | L= clearance to a mechanical air supply inlet [*min. 72" (1.8 m) |
E= Clearance to unventilated soffit [12" (30 cm) min.] | M= **clearance above paved |
F= Clearance to outside corner: with AstroCap Termination Cap (min 6"/15cm), with | located on public property [*84" (2.1 m) min.] |
N=clearance under veranda, porch,, deck, or balcony [*12" | |
G= Clearance to inside corner: withAstroCapTermination Cap (min 6"/15cm), with Dura- | (30 cm) min.***] |
Vent Termination Cap (12"/30cm) |
|
*As specified in CGA B149 or ANZI 223.1 Installation Codes. Note: local Codes or Regulations may require different clearances.
**A vent shall not terminate directly above a
***Only permitted if veranda, porch, deck or balcony, is fully open on a minimum of 2 sides beneath the floor.
EXTERIOR VENT TERMINAL LOCATIONS
INSTALLATION