DV STOVE HORIZONTAL VENT KIT

INSTALLATION

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) include all the parts needed to install the C34 with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown on page 17.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter

2)1 Flex Liner, compressed aluminium 2 ply liner, 4" (102mm) inside diameter

3)4 spring spacers

4)1 90 deg. Elbow

5)1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pieces

6)1 Thimble Cover

7)1 Wall Thimble (2 pcs.)

8)1 Adapter

9)1 AstroCap Termination Cap

10)2 Trim Collar

11)1 tube of Mill-Pac, high temperature sealant

12)12 Screws, #8 x 1/2" Self tapping, Stainless Steel

13)14 Screws, #8 x 1/2" Self tapping, Black

14)4 Screws #8 x 1-1/2" Drill Point, Black

15)4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)8 Wood screws #8 x 1"

Optional:

946-206 Vinyl Siding Standoff

for AstroCap

Note:

a)Liner sections should be continuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufacturer's products.

DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness.

Refer to pages 6 to 10 for vent location and clearance dimensions.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no ob- structions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be maintained except that only a 1" (25mm) clear- ance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildup may oc- cur. Be sure to check vent termination area after snow falls, and clear to pre- vent accidental blockage of venting sys- tem. When using snow blowers, make

sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the vertical center-line for the vent termina- tion.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241 mm) square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior andexteriorwallwith4woodscrews (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe section to the vent terminal and slide into position from the exterior. The larger diameter end of the ad- justable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline of the starter collar on the unit.

Note: if the centerline cannot be met, the adjustable sections will have to be cut.

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

15