OPTIONAL FAN INSTALLATION

INSTALLATION

OPTIONAL FAN INSTALLATION

For pedestal unit: To install the fan in an installed stove-access from front through the pedestal by following the directions below. If the stove is not installed - access through rear and follow steps 4 to 17.

For leg unit: remove 7 screws, remove bottom access panel and install fan assembly, follow steps 4 to 17.

IMPORTANT

Disconnect power supply

before servicing

2)Remove valve cover plate by removing 2 screws.

3)Remove wire from piezo ignitor.

4)Screw the four 8-32 x3/4 screws provided into the nutserts as shown in diagram 3. Do not tighten screws.

5)Push all the fan wires through the hole on the fan assembly. See diagram 2.

Diagram 2

9)Lift the fan assembly in through the pedestal and up through the cut out as shown in diagrams 3 and 4.

1)Open pedestal door and remove door cov- er plate by removing 4 screws. See dia- gram 1.

6)Put power cord (shown in diagram 3) through the hole and pull through to the front of the unit for easier installation of ground wire.

7)Place the fan assembly partially in door cover plate hole. See diagram 2.

8)Attach the 2 ground wires (green) to the ground lug as per diagram 2.

Note: Ground lug is located on the bot- tom of the fan assembly. See diagram 2.

Diagram 3

Diagram 1

Diagram 4

 

Caution: Ensure that the wires do not touch any hot surfaces.

Note: The #8 ground lug is a dedicated ground for mobile home use only.