OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed.

5)Verify that the venting is unobstructed.

6)Verify log placement. If the pilot cannot be seen when lighting the unit - the logs have been incorrectly positioned.

7)The unit should never be turned off, and on again without a minimum of a 60 second wait for purging.

Note: Clean fingerprints off the gold before lighting stove.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, remove one glass panel/door.

Only when the pilot holds, without pressure being applied to the control knob, resecure the glass panel to the unit. The unit must not be operated with the glass removed.

IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. De- press the gas control knob fully. Depress the igniter button several times until the pilot lights. After approximately one minute, re- lease the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" posi- tion.

5)Use the ON/OFF switch, wall switch, ther- mostat or remote control to turn on the unit.

6)Rotate the flame height regulator (Hi/Lo) to adjust the flame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the ON/OFF switch, wall switch, ther- mostat or remote control to turn off the burner.

2)Push in the PILOT knob slightly and turn clockwise to off. Do not force.

3)Turn off all electric power to the appliance if service is to be performed.

FIRST FIRE

The first fire in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke de- tectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down. DO NOT ATTEMPT TO

CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appliance is lit, it may cause con- densation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleanedorthefilmwillbake on and become very difficult to re- move. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pattern, contact your Regency dealer for further instructions.

Top View of pilot flame

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or thermopile or thermocouple.