INSTALLATION
DOOR HANDLE
Attach spring handle by rotating counter clock- wise onto rod. Ensure that the spring fits into the entire length of the rod.
CAUTION
Do not wire millivolt remote
control wires to the 120V AC wires
3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.
CAUTION
Do not wire millivolt wall thermo- stat wires to the 120V AC wires
Note: Preferable if the thermostat is installed on an interior wall.
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
DO NOT TRY TO TURN
DOOR HANDLE!
IT IS NOT DESIGNED
OPTION 2: REMOTE
WALL SWITCH
1)Run the wire through the opening in the rear of the unit. Be careful not to damage any wires.
Wire Size | Max. Length |
| |
14 GA. | 50 | Ft. |
|
16 GA. | 32 | Ft. |
|
18 GA. | 20 | Ft. |
|
20 GA. | 12 | Ft. |
|
22 GA. | 9 | Ft. |
|
|
|
|
|
TO BE MOVED.
OPTION 1: REMOTE
CONTROL
INSTALLATION
Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver (protection from extreme heat is very important). Run wires from the fireplace to that location. Use the Thermostat Wire Table.
2)Connect the two wires to the gas valve. See diagram below.
Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run use the Thermostat Wire Table.
2)Connect the wire to the wall switch and install into receptacle box.
CAUTION
Do not wire millivolt wall switch for gas appliance to the 120V AC wires
OPTION 3: WALL
THERMOSTAT
INSTALLATION
Regency offers an optional programmable ther- mostat but any
Connect the wires as per the wiring diagram. Use the Thermostat Wire Table to determine the maximum wire length.
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:
1)Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.
2)If required, adjusting the primary air to en- sure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)Check for proper draft.
CAUTION
Any alteration to the product that caus- es sooting or carboning that results in damage to the unit is not the re- sponsibility of the manufacturer and will not be covered by the warranty.
26 | Regency CLASSIC |