Regency C34-NG2 Installation, Rigid Pipe Venting Systems, Horizontal or Vertical Terminations

Models: C34-LP2 C34-NG2

1 36
Download 36 pages 10.08 Kb
Page 12
Image 12
RIGID PIPE VENTING SYSTEMS

INSTALLATION

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Alternate

Horizontal

Termination

Caps

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Dura-Vent Flue Adaptor in conjunction with Selkirk Direct-Temp and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WHI listing of components.

When using piping other than Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPITM, and FPI AstroCapTM are the proprietary trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.