Regency C34-LP2, C34-NG2 Installation, Save These Instructions, Specifications, Before You Start

Models: C34-LP2 C34-NG2

1 36
Download 36 pages 10.08 Kb
Page 5
Image 5
INSTALLATION

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The CLASSIC Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

- WARNING -

Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

Note: These instructions take prece- dence over Simpson Dura-Vent instructions

SPECIFICATIONS

Fuels: C34-NG is approved for use with natural gas. C34-LP is approved for use with liquefied petroleum gases (propane).

Electrical: 120V. A.C. system.

Optional circulation fan: Two speed, 125/

75 CFM.

Log Sets: Ceramic fibre, 4 per set.

Vent System: Coaxial (6 5/8" outer/ 4" inner liner) rigid flue and termination cap.

SHOULD OVERHEATING OCCUR, OR THE GAS SUPPLY FAIL TO SHUT OFF, SHUT OFF THE MANU- AL GAS VALVE TO THE APPLI- ANCE BEFORE SHUTTING OFF THE ELECTRICAL SUPPLY.

- WARNING -

Risk of fire or electric shock. Only qualified service personnel shall be used to install and provide main- tenance of this appliance.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

THIS APPLIANCE SHOULD BE IN- STALLED, REPAIRED, INSPECT- ED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERV- ICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CAR- PETING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPART- MENT, BURNER AND CIRCULAT- ING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR- RANTY.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servic- ing, proper operation and around the air openings into the combustion chamber.

2)The appliance may be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can

be raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, see clearances to combustibles on page 6.

The CLASSIC Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner. This appliance is Listed for Alcove installations, maintain minimum Alcove clear- ances as follows, minimum ceiling height of 65-11/16", minimum width of 48" and a maximum depth of 36".

3)TheCLASSICDirectVentFreestandingGas Stove is approved for alcove installations, which meet the clearances listed on page6. This unit can be installed in a bedroom, when installed with a millivolt thermostat. This unit is approved for manufactured home instal- lations, see page 13 for the required vent arrangements. If installed into a manufac- tured or mobile home the unit must be bolted down to the floor.

4)We recommend that you plan your installa- tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or Na- tional Electrical Codes,CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Cana- dian Electrical Code.

3)The appliance should be inspected for shipping damage before use and serviced annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, etc. It is imperative that control compartments, and circulating air passage- ways of the appliance be kept clean.

4)See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area.

5)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope.