Regency C34-NG2, C34-LP2 Installation, Horizontal Venting with Two 2 90o Elbows, Option, H + H1

Models: C34-LP2 C34-NG2

1 36
Download 36 pages 10.08 Kb
Page 14
Image 14
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

 

Option

 

V

H + H1

 

A)

4'

Min.

6' Max.

 

B)

5'

Min.

7' Max.

 

C)

6' Min.

8' Max.

With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Lengths do not include elbow indicated.

Vent restrictor position C (fully open), refer to page 9.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

H

V + V1

With these options, max. total

A)

1' Min.

4' Max.

2' Min.

pipe length is 30 feet with min.

B)

2' Min.

5' Max.

3' Min.

of 6 feet total vertical and max.

 

 

 

 

8 feet total horizontal.

C)

3' Min.

6' Max.

4' Min.

Please note min. 1 foot

D)

4' Min.

7' Max.

5' Min.

between 90o elbows is re-

E)

5' Min.

8' Max.

6' Min.

quired.

 

 

 

 

 

Lengths do not include elbow indicated.

 

Vent restrictor position C (fully open), refer to page 9.

 

 

 

 

 

14

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Page 14
Image 14
Regency C34-NG2 Installation, Horizontal Venting with Two 2 90o Elbows, Vertical Venting with Two 2 90o Elbows, Option