Regency C34-NG2 Installation Checklist, Locating Your Classic Gas Stove, This includes

Models: C34-LP2 C34-NG2

1 36
Download 36 pages 10.08 Kb
Page 6
Image 6
INSTALLATION

INSTALLATION

6)Never vent to another room or inside a building. Make sure that the vent is fitted as per the instructions starting on page 8.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Venting terminals shall not be recessed into a wall or siding.

9)Any safety glass removed for servicing must be replaced prior to operating the appliance.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)

Locate appliance, page 6, see Clearances

 

to Combustibles, page 6. Check Venting

 

Clearances, Vertical and Horizontal Termi-

 

nation requirements on pages 11 to 14.

2)

Install Optional Fan, page 7.

3)

Assemble stove base - pedestal or bottom

 

shield and legs, page 8.

4)

Install venting, either with the DV Stove

 

Horizontal Vent Kit (page 15) or the Dura-

 

Vent Termination kits (page 17). Check Vent

 

Restrictor setting, page 9. If converting a

 

Class-A Metal Chimney or Masonry Chim-

 

ney to a Direct Vent system, see instruc-

 

tions on pages 22 and 23.

5)

Make gas and electrical connections, page

 

24. Test the pilot. Must be as per diagram,

 

pages 28.

6)

Test gas pressure, page 24.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

3)Check for proper draft.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufac- turer.

LOCATING YOUR

CLASSIC

GAS STOVE

When selecting a location for your stove, en- sure that the clearances on this page are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/Alcove

For Vent Termination requirements, see pages 10 to 11.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM dis- tances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearanc- es do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the back is too close, move the stove until the correct clearance to the back is obtained.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with the unit) is installed.

This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams below:

 

C34 Clearance to Combustibles

A

Side Wall to Unit

10"/250mm

B

Back Wall to Unit

6"/ 150 mm

E

Side Wall to Unit

1.5"/ 38 mm

 

 

 

 

C34 Reference Dimensions

C

Back Wall to Flue Centerline

13"/330mm

D

Side Wall to Flue Centerline

22"/559mm

F

Side Wall to Flue Centerline

14"/356mm

7) Install log set, see page 25.

.

8)Install optional Wall Switch, Remote Control, or Wall Thermostat, page 26.

9)Final check, page 26.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to cus- tomer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See page 7.

3)Appliance must be anchored to the floor. See page 8.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air is not required.

Minimum ceiling height is 36" / 914 mm from top of unit.

Minimum clearance to vent 1-1/4" (32mm).

6

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Page 6
Image 6
Regency C34-NG2 Installation Checklist, Locating Your Classic Gas Stove, Clearances To Combustibles, This includes