MAINTENANCE

HYDRAULIC FLUID

Maintaining the proper hydraulic oil level and oil cleanliness is very important for continued trouble-free operation of the mower. The fluid level should be checked daily before the mower is put into service. A visual inspection of the hydraulic connections, hose guards and shielding should occur daily as well. The hydraulic fluid can loose its ability to lubricate in a number of different ways, most commonly contamination and overheating. Both scenarios can lead to catastrophic failure of the hydraulic components and costly repairs. Rhino offers fluids, filters, and oil analysis capabilities to help you maintain your hydraulic powered machine. Please be sure to follow the oil & filter change procedure that is outlined for your mower.

Product

Oil Type

Oil

ISO

Filter Change
Oil Change
Specification
Cleanliness

Recommendation

Recommendation

 

 

 

 

 

 

 

 

DB150

UTF

Chevron 1000

18/16/14

First 100 / every 500

First 500 / every 1000

 

 

THF

 

or 12 months

or 12 months

 

 

 

 

 

 

The above are prescribed intervals, but frequency may change based on use. It is important to monitor the filter clogging indicator.

There are many comparable oils that are equivalent to what is used by the factory. An ISO class oil with a viscosity that matches your operating conditions is recommended. For further information, please consult with the oil manufacturer for proper specifications.

MAINTENANCE

DB150 07/11

Maintenance Section 5-5

©2011 Alamo Group Inc.

Page 157
Image 157
Rhino Mounts DB150 Hydraulic Fluid, Maintenance, Product, Oil Type, Filter Change, Oil Change, Specification, Cleanliness