System Settings

Parallel Interface

This section describes the user tools in the Parallel Interface menu under Interface Settings. [Parallel Interface] is displayed when this machine is installed with the IEEE 1284 interface board.

Parallel Timing

 

 

2

Sets the timing for the control signal of the parallel interface.

 

The default setting is ACK outside.

Parallel Comm. Speed

Sets the communication speed for the parallel interface. The default setting is High Speed.

Selection Signal Status

Sets the level for the select signal of the parallel interface. The default setting is High.

Input Prime

Sets whether to validate or invalidate the input prime signal upon reception. The default setting is Inactive.

Bidirectional Comm.

Sets the printer's response mode to a status acquisition request when using a parallel interface.

The default setting is On.

When set to [Off], bidirectional communication function will be disabled, and the printer driver will not be installed under Windows Auto Detect function.

Signal Control

Specify how error during printing or sending facsimile from the computer is to be dealt with.

The default setting is Job Acceptance Priority.

Reference

p.4 “Accessing User Tools”