ASSEMBLY

TO CHECK THE THROAT PLATE

See Figure 16.

WARNING:

The throat plate must be level with the saw table. If the throat plate is too high or too low, the workpiece can catch on the uneven edges resulting in binding or kickback which could result in serious personal injury.

To align the throat plate with the saw table:

Lower the blade by turning the height/bevel adjusting handwheel counterclockwise.

Loosen the screw in the throat plate.

Using a 3/32 in. hex key, adjust the four set screws as shown in figure 16.

Retighten the screw being careful not to overtighten which can cause the throat plate to bow or bend.

TO REMOVE/REPLACE THE THROAT PLATE

See Figure 17.

Unlock the blade height lock knob.

Lower the blade by turning the height/bevel adjusting handwheel counterclockwise.

Loosen the screw in the throat plate.

Lift the throat plate from the front end and pull toward the front of the saw.

Place throat plate into throat plate opening in table and push toward rear of saw to engage spring clip until key slot in throat plate will drop over flat head screw.

Retighten the screw being careful not to overtighten which can cause the throat plate to bow or bend.

SET SCREWS

Fig. 16

REMOVING THROAT PLATE

Fig. 17

 