MAINTENANCE

BRUSH REPLACEMENT

See Figure 61.

Unplug the saw.

Lower blade completely and bevel to 45º. Lock the blade.

Turn saw upside down.

Remove brush caps with a screwdriver.

NOTE: Brush assembly is spring load and will pop out when brush cap is removed.

Remove brush assemblies and check for wear.

Replace both brushes when either has less than 1/4 in. length of carbon remaining. Do not replace one side without replacing the other.

Reassemble using new brush assemblies by reversing the steps listed above. Make sure curvature of brush matches curvature of motor and that brush moves freely in brush tube.

Tighten all brush caps securely. Do not overtighten.

BRUSH

CAP

BRUSH

ASSEMBLY

Fig. 61

ACCESSORIES

Look for these accessories where you purchased this product:

AC1022 Miter Gauge Hold Down

AC1040 Molding/Dado Throat Plate

AC1045 Zero Clearance Throat Plate

AC9933 Flip Top Portable Work Support

WARNING:

Current attachments and accessories available for use with this tool are listed above. Do not use any attachments or accessories not recommended by the manufacturer of this tool. The use of attachments or accessories not recommended can result in serious personal injury.