Step 6.3.1 Coupling and Tube Assembly (Continued)

BH-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Step 6.3.1 Coupling and Tube Assembly (Continued)

Tighten slide bar as shown below.

 

Drive slide bar until tight.

 

End of slide bar should be

 

within tolerance listed below.

 

± 2" (5 cm)

Correct slide bar

Incorrect slide bar

dimensions

 

position

• Repeat Step 6.3 A - D until all tubes are assembled. See Page 20, Step 6.3.2.

Step 6.3.2 Coupling and Tube Assembly (Continued)

7' 6" ± 1'

(2.3 m ± .25 m)

10' ± 1'

(3 m ± .25 m)

 

Tube Length

Model

Minimum

 

 

BH-40

10' (3 m)

 

 

BH-60

20' (6 m)

 

 

BH-80

20' (6 m)

 

 

BH-100

30' (9 m)

 

 

BH-115

30' (9 m)

 

 

BH-125

40' (12 m)

 

 

BH-140

40' (12 m)

 

 

BH-150

50' (15 m)

 

 

BH-175

50' (15 m)

 

 

BH-200

60' (18 m)

 

 

Total Overall Tube Length