Roberts Gorden CTHN-60 12 Restrictor Plate Installation, 13 Fan Installation, Description, Model

Models: CTHN-60 CTHN-150 CTHN-175 CTHN-80 CTHN-125 CTHN-40 CTHN-100 CTHN-200

1 48
Download 48 pages 22.1 Kb
Page 31
Image 31
Step 8.12 Restrictor Plate Installation

SECTION 8: UNITARY LINEAR & U-TUBE HEATER INSTALLATION

Step 8.12 Restrictor Plate Installation

Attach restrictor plate (see chart below right) to fan inlet and replace inlet collar.

Description

Part Number

Restrictor Plate

07730XXX

 

 

Model

Fan Assy. P/N

Restrictor Plate P/N

CTHN-40

05220000

07730400 1.25'' dia

 

 

 

 

CTHN-60

05220000

07730100

1.50'' dia

 

 

 

CTHN-80

05220000

NONE

 

 

 

 

CTHN-100

05220000

07730500

2.25'' dia

 

 

 

 

CTHN-125

05220000

07730500

2.25'' dia

 

 

 

 

CTHN-150

05220000

07730700

2.75'' dia

 

 

 

 

CTHN-175

05221000

07730600

2.50'' dia

 

 

 

CTHN-200

05221000

NONE

 

 

 

 

Step 8.13 Fan Installation

Fold tab around outside of tube nearest to the vent to hold turbulator in place.

Last Tube

Remove warning tag from fan inlet and install restrictor plate if required.

See Step 8.12.

Turbulator not required

for all models. (See Page 21, Step 8.8 for details.)

Tighten securely Fan Assy. P/N until tube cannot

be removed.

Vent Adapter

Description

Part Number

Fan Assembly 40 -150

05220000

 

 

Fan Assembly 175-200

05221000

 

 

Step 8.13 Fan Installation Fan Assembly

25

Page 31
Image 31
Roberts Gorden CTHN-60, CTHN-200 12 Restrictor Plate Installation, 13 Fan Installation, Description, Part Number, Model