SECTION 9: MULTIBURNER HEATER INSTALLATION

Step 9.9 Coupling and Tube Assembly

Close coupling

Start slide bar/coupling lock

A with tab.

B onto coupling.

 

Tab

 

 

 

Slide Bar/Coupling Lock

 

 

Wide End

 

 

Coupling

Open

3" (8 cm) to

 

 

 

 

4" (10 cm)

 

Closed

 

 

C Insert tubes into coupling.

D Tighten coupling to join tubes.

 

 

Slide Bar/Coupling Lock

 

Orient coupling so that

Coupling

 

the impact block is in the

 

 

2:00 or 10:00 o’clock

 

 

positions.

Tube

 

Tube

 

 

Tube

Description

Part Number

Coupling

01329600

 

 

Slide Bar/Coupling Lock

01329700

 

Tube

91409XXX

Step 9.9.1 Coupling and Tube Assembly (Continued)

Tighten slide bar as shown below.

 

Drive slide bar until tight.

 

End of slide bar should be

 

within tolerance listed below.

 

± 2" (5 cm)

Correct Slide Bar

Incorrect Slide Bar

Dimensions

 

Position

Repeat Step 9.9 on Page 37, A - D until all tubes are assembled. See Page 38, Step 9.9.2.

NOTE: If coupling is not tight, loss of vacuum can occur.

37

Page 43
Image 43
Roberts Gorden CTHN-125, CTHN-200, CTHN-100, CTHN-40, CTHN-80, CTHN-175, CTHN-150, CTHN-60 service manual ± 2 5 cm