RoboteQ AX2550, AX1500 user manual Amps Limit, Bit Definition See pages

Models: AX2550 AX1500

1 186
Download 186 pages 53.05 Kb
Page 136
Image 136

Serial (RS-232) Controls and Operation

This parameters selects the various open loop and closed loop operating modes as well as the feedback method.

Bit

Definition

 

 

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop

page 40

 

 

(default)

page 93

 

 

 

 

 

 

1

= A & B mixed speed open loop

page 81

 

 

 

 

 

 

2

= A speed open loop, B position

 

 

 

3

= A & B position

 

 

 

4

= A & B separate speed closed loop

 

 

 

5

= A & B mixed speed closed loop

 

 

 

6

= A speed close loop, B position

 

 

 

 

 

 

6:3

Reserved

 

 

 

 

 

 

 

6

Ch1 Feedback type

0 = Analog

page 93

 

 

1

= Encoder

page 81

 

 

 

 

7

Ch2 Feedback type

0 = Analog

 

 

 

1

= Encoder

 

 

 

 

 

 

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow- ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

 

 

See pages

 

 

 

 

3:0

Coarse Amps

0 = 7.5A

page 42

 

 

1

= 11.25A

 

 

 

2

= 15A

 

 

 

3

= 18.75A

 

 

 

4

= 22.5A

 

 

 

5

= 26.25A (default)

 

 

 

6

= 30A

 

 

 

 

 

7:4

Fine Amps

Mutliply this number by 0.25 and sub-

 

 

 

stract result from the Coarse Amps value

 

 

 

 

 

 

136

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 136
Image 136
RoboteQ AX2550, AX1500 user manual Amps Limit, Bit Definition See pages