Serial (RS-232) Controls and Operation

Syntax:^FF

Reply:+ Success, changed parameters are now active

-if error

Table 22 below lists the complete set of configuration parameters that may be accessed and changed using RS232 commands.

Flash Configuration Parameters List

TABLE 22. Configuration parameters in Flash

Location

Description

Active after

 

 

 

^00

Input control mode

Reset

 

 

 

^01

Motor Control mode and Closed Loop Feedback type

Reset or ^FF

 

 

 

^02

Amps limit

Reset or ^FF

 

 

 

^03

Acceleration

Reset or ^FF

 

 

 

^04

Input Switch function

Reset or ^FF

 

 

 

^05

reserved

 

 

 

 

^06

Joystick Deadband or Analog Deadband

Reset or ^FF

 

 

 

^07

Exponentiation on channel 1

Instant

 

 

 

^08

Exponentiation on channel 2

Instant

 

 

 

^09

Reserved

 

 

 

 

^0A

Left / Right Adjust

Reset or ^FF

 

 

 

^0B

Encoder 1 Time Base when Encoder Present

Reset or ^FF

 

 

 

^0C

Encoder 2 Time Base when Encoder Present

Reset or ^FF

 

 

 

^0D

Reserved

 

 

 

 

^0E

Encoder Distance Divider when Encoder Present

Reset or ^FF

 

 

 

^0F

Gain Integral for PID

Reset or ^FF

 

 

 

^10

Gain Diff for PID

Reset or ^FF

 

 

 

^11

Gain Prop for PID

Reset or ^FF

 

 

 

^12

Joystick Center 1 MS

Instant

 

 

 

^13

Joystick Center 1 LS

Instant

 

 

 

^14

Joystick Center 2 MS

Instant

 

 

 

^15

Joystick Center 2 LS

Instant

 

 

 

^16

Joystick Min 1 MS

Instant

 

 

 

^17

Joystick Min 1 LS

Instant

 

 

 

^18

Joystick Min 2 MS

Instant

 

 

 

^19

Joystick Min 2 LS

Instant

 

 

 

^1A

Joystick Max 1 MS

Instant

 

 

 

^1B

Joystick Max 1 LS

Instant

 

 

 

134

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 134
Image 134