Connecting devices to Output C

TABLE 8. DB15 connector pin assignment

Pin

Input or

Signal depending

 

Number

Output

on Mode

Description

 

 

RC/RS232: Ana in 2

Channel 2 speed or position feedback input

 

 

 

 

10

Analog in

Analog: Command 2

Analog command for channel 2

 

 

 

 

11

Analog in

RC/RS232: Ana in 1

Channel 1 speed or position feedback input

 

 

 

 

 

 

Analog: Command 1

Analog command for channel 1

 

 

 

 

12

Analog in

RC: Unused

 

 

 

 

 

 

 

RS232: Ana in 3

Analog input 3

 

 

 

 

 

 

Ana: Ana in 3

Channel 1 speed or position feedback input

 

 

 

 

14

Power Out

+5V

+5V Power Output (100mA max.)

 

 

 

 

15

Input

Input EStop/Inv

Emergency Stop or Invert Switch input

 

 

 

 

**These connections should only be done in RS232 mode or R/C mode with radio pow- ered from the controller.

Connecting devices to Output C

Output C is a buffered, Open Drain MOSFET output capable of driving over 2A at up to 24V.

The diagrams on Figure 23 show how to connect a light or a relay to this output:

+

5 to

24V DC

-

Relay, Valve Motor, Solenoid

or other Inductive Load

 

 

 

 

 

 

 

Internal

 

 

 

 

 

 

 

Output C 1,9

 

 

 

 

 

Transistor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights, LEDs, or any other non-inductive load

+

 

5 to

 

24V

 

DC

Output C 1,9

-

 

Internal Transistor

Ground 5

Ground 5

FIGURE 23. Connecting inductive and resistive loads to Output C

This output can be turned On and Off using the Channel 3 Joystick when in the R/C mode. See “Activating the Accessory Outputs” on page 110 for more information.

When the controller is used in RS232 mode, this output can be turned On and Off using the !C (On) and !c (Off) command strings. See “Controller Commands and Queries” on page 128 for more information.

AX1500 Motor Controller User’s Manual

55

Page 55
Image 55
RoboteQ AX1500, AX2550 user manual Connecting devices to Output C