RoboteQ AX1500 Acceleration, Input Switches Function, Address, Access, Read/Write, Effective

Models: AX2550 AX1500

1 186
Download 186 pages 53.05 Kb
Page 137
Image 137
Acceleration

Accessing & Changing Configuration Parameter in Flash

Acceleration

Address:

^03

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the rate at which the controller internally changes the command value from the one it was to the one just received.

Bit

Definition

See pages

 

 

 

7:0

0 = very slow

See “Programmable Acceleration”

 

1

= slow

on page 45 for complete list of

 

acceptable values

 

(2) = medium-slow (default)

 

 

 

3

= medium

 

 

4

= fast

 

 

5

= fastest

 

 

 

 

 

Input Switches Function

Address:

^04

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter enables and configures the effect of the controller’s Digital Inputs and other settings.

Bit

Definition

 

See pages

 

 

 

 

1:0

Enable and

(00) = Input Disabled (default)

page 49

 

Configure

01 = Input as Emergency Stop

page 49

 

Invert/Estop

 

10 = Disabled

 

 

 

 

 

 

11 = Input as Invert Command

 

 

 

 

 

2

Output C when

(0) = No Action (default)

page 49

 

Motor On

1 = Output C On when either motor is On

 

 

 

 

 

 

 

 

3

Encoder Safety

(0) = No Action (default)

page 72

 

 

1 = Disables Controller if Encoder detects

 

 

 

no movement while power is applied to

 

 

 

the motors

 

 

 

 

 

AX1500 Motor Controller User’s Manual