Operating Modes Registers

Serial (RS-232) Controls and Operation

TABLE 23. Runtime R/W Parameters list

Location

Function

R/W

 

 

 

^86

PID Differential gain 1

R/W

 

 

 

^87

PID Differential gain 2

R/W

 

 

 

^88

PWM frequency

R/W

 

 

 

^89

Controller Status

R Only

 

 

 

^8A

Controller Model

R Only

 

 

 

^8B

Current Amps limit 1

R Only

 

 

 

^8C

Current Amps limit 2

R Only

 

 

 

Important Notice:

Do not write in the locations marked as Read Only. Doing so my cause Controller malfunction.

Operating Modes Registers

Address:

^80 - Channel 1

 

^81 - Channel 2

Access:

Read/Write

Effective:

Instantly

Modifying the bits in the Operating Mode registers will change the controller’s operating modes on-the fly. Changes take effect at the controller’s next 16ms iteration loop. After reset, these bits get initialized according to the configuration contained in Flash.

Values are in Hexadecimal.Example: 00000101 = Hex 05

TABLE 24. Operating Modes Register Definition

Bit

7 to 3

2

1

0

Function

Not Used

0:Open Loop

1:Closed Loop

(when in Speed Mode)

0:Speed Mode

1:Position Mode

0:Analog Feedback

1:Encoder Feedback

Read/Change PID Values

Address: ^82 - P1 ^83 - I1 ^84 - D1 ^85 - P2

142

AX1500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007